Photometer 5010 V5+

Made in Germany

TECHNICAL SPECIFICATIONS

Photometer 5010 V5+        Arbeitsraum Photometer 5010 V5+

Type

Semi-automatic, single-beam filter photometer

Light Source

Halogen lamp - 12 V, 20 W with protection for lifetime

Wavelength

340 nm - 800 nm

Wavelength Selection

Automatic via 9-position filter wheel :
6 standard interference filters: 340 nm, 405 nm, 492 nm, 546 nm, 578 nm and 623 nm;
3 positions for optional filter of choice

Photometric Range

0 - 2.5 A

Cuvette System

Micro flow cell: 32 µl, 10 mm light path interchangeable with normal standard cuvettes (macro or semi-micro, disposable or special optical glass)

Temperature Control

  • Internal Peltier element, temperature variable, pre-adjusted to 25 °C, 30 °C and 37 °C
  • Equilibration time for aspirated reaction mixture to reach 37 °C from ambient temperature: 15 sec

Aspiration System

Built-in peristaltic pump driven by stepper motor, programmable aspiration volume controlled by infrared light barrier

Sipping Volume

  • Minimum 250 µl, typically 500 µl up to 2000 µl
  • Separate setting of aspirate volume and wash volume

Operator Interface

Touchscreen for direct functions and alphanumerical inputs

Data Presentation

Graphic display: white characters or symbols, blue backlight, dimension 240 * 128 dots

Integrated Printer

Dot-matrix printer, 24 characters per line

Languages

English and French / German / Indonesian / Russian / Spanish

Memory

  • General operating software can be updated by PC
  • Reagent open system with capacity for up to 231 programmable methods
  • Import of data by touchscreen or PC
  • Up to 50 non-linear calibration curves with max 20 sets of points can be stored

Data Logging

Up to 1000 results can be saved in the memory

Signal Port

Serial port for connection to an external printer and/or PC

Measurement Procedures

  • Absorbance
  • End Point with factor, standard or multiple standards, with or without reagent blank and/or sample blank
  • Bichromatic end point
  • Kinetics with standard, factor or multiple standards, with or without blank
  • Fixed time with standard, factor or multiple standards, with or without reagent blank
  • Turbidimetry
  • Single, double and triple determinations
  • Curve fitting for non-linear standard curves
  • Free hemoglobin in combination with optional interference filters

Quality control

Up to 50 methods can be controlled with two control sera
Levey Jennings plot

Measuring Time

  • Kinetic: variable from 3 - 25 deltas, time per delta 4 - 255 sec in 1 sec steps
  • Fixed time: variable from 0 - 65535 sec in 1 sec steps

Delay Time

Programmable from 0 - 65535 sec in 1 sec steps

Mains Supply

Range: 100 VAC up to 264 VAC at 50/60 Hz

Dimensions

Length 33 cm x width 34 cm x height 18 cm

Weight

5,3 kg